Part Number Hot Search : 
20M16 GBPC1508 AS324G MCT210M M2500 S25C64 JANTX2N TNY176
Product Description
Full Text Search
 

To Download GL390 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 GL390/GL390V
GL390/GL390V
s Features
1. Thin bow type resin mold package (Resin area : 2.0 x 3.1 x 5.2 mm) 2. Low peak forward voltage ( GL390V) VFM : TYP. 1.9V at IFM=0.5A
Thin Bow Type Resin Mold Package Infrared Emitting Diodes
s Outline Dimensions
(Unit : mm)
3.8 0.3 3.1
g1
Epoxy resin
2.0 + 0.1 - 0.3
1
s Applications
1. Cameras 2. Infrared remote controllers
Protruded resin
0.2 + 0.5 - 0.2
5.2 0.3
4.1
0.8 MAX.
2 24.0 MIN.
1 Anode 2 Cathode
2 - 0.5 0.1 (1.0) 1 2
2 - 0.5 0.1
(2.54)
g 1 Resin type
GL390
* Tolerance : 0.2mm
Pale blue transparent resin Blue transparent resin
GL390V
s Model Lineup
Model Radiant intensity (mW/sr) Half intensity angle ( ) GL390 TYP. 13 TYP. 18 GL390V TYP. 16
s Absolute Maximum Ratings
Parameter Forward current *1 Peak forward current Reverse voltage Power dissipation Operating temperature Storage temperature *2 Soldering temperature Symbol IF IFM VR P T opr T stg T sol Rating 60 1 6 150 - 25 to 85 - 40 to 85 260
(Ta=25C) Unit mA A V mW C C C
*1 Pulse width <=100 s, Duty ratio=0.01 *2 For 3 seconds at the position of 2.6 mm from the resin edge
" In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device."
GL390/GL390V
s Electro-optical Characteristics
Parameter Forward voltage Peak forward voltage Reverse current
*3
(Ta=25 C ) Symbol VF Conditions IF = 50mA IFM = 0.5A VR = 3V IF = 50mA IF = 5mA IF = 5mA VR = 0 f = 1MHz MIN. 7 9 TYP. 1.3 2.2 1.9 13 16 950 45 70 50 300 18 MAX. 1.5 3.5 3.0 10 Unit V V A mW/sr nm nm pF kHz
GL390 GL390V GL390 GL390V
V FM IR IE P
Radiant intensity Peak emission wavelength Half intensity wavelength Terminal capacitance Response frequency Half intensity angle
GL390 GL390V
Ct fc
IF = 20mA
*3
I E : Value obtained by converting the value in power of radiant fluxes emitted at the solid angle of 0.01 sr (steradian) in the direction of mechanical axis of the lens portion into 1 sr or all those emitted from the light emitting diode.
Fig. 1 Forward Current vs. Ambient Temperature
120
Fig. 2 Peak Forward Current vs. Duty Ratio
10000 5000
Pulse width <=100 s Ta = 25C
(mA)
80
FM
(mA)
1000 500
100
F
60
40
Peak forward current I
Forward current I
100 50
20
0 - 25
10 0 25 50 75 85 100 125 10
-3
10
-2
10
-1
1
Ambient temperature Ta (C )
Duty ratio
GL390/GL390V
Fig. 3 Spectral Distribution
100 Ta = 25C I F = 5mA
Fig. 4 Peak Emission Wavelength vs. Ambient Temperature
1000
Relative radiant intensity (%)
80
Peak emission wavelength p (nm)
I F = const.
975
60
950
40
925
20
0 880
900
920
940
960
980 1000 1020 1040
900 - 25
0
25
50
75
100
Wavelength (nm)
Ambient temperature Ta ( C )
Fig. 5-1 Forward Current vs. Forward Voltage (GL390)
500
Fig. 5-2 Forward Current vs. Forward Voltage (GL390V)
1000 + 50C + 25C 0C + 85C - 25C 100
Ta= 75C (mA) 50C
100 50 20 10 5 2 1 0 0.5 1.0 1.5 2.0 2.5
F
25C 0C - 20C
F
Forward current I
Forward current I
F
(mA)
10 1 0
200
3.0
3.5
0.5
1.0
1.5
2.0
F
2.5
3.0
Forward voltage V
(V)
Forward voltage V
(V)
Fig. 6 Relative Radiant Flux vs. Ambient Temperature
20 10
Fig. 7 Radiant Intensity vs. Forward Current
1000 Ta=25C Pulse width 100 s Duty ratio=0.01 : DC : Pulse
GL390V
IF = const. (mW/sr)
E
100
Relative radiant flux
5 2 1 0.5 0.2 0.1 - 25 0 25 50 75 100
Radiant intensity I
10
GL390
1
0.1
0.01 0.1
1
10
100
1000
Ambient temperature Ta ( C)
Forward current I F (mA)
GL390/GL390V
Fig. 8-1 Radiation Diagram (Horizontal Direction)
- 20 - 30
Relative radiant intensity (%)
Fig. 8-2 Radiation Diagram (Vertical Direction)
- 40 - 30 - 20 - 10 0 + 10+ 20 + 30 + 40
- 10
0
+ 10
+ 20 + 30
- 50
Relative radiant intensity (%)
+ 50
- 40
+ 40
- 60
+ 60
- 50 - 60 - 70 - 80 - 90
+ 50 - 70 + 60 + 70 + 80 - 80
+ 70
+ 80
0
+ 90
- 90
0
+ 90
Angular displacement
Angular displacement
q Please refer to the chapter "Precautions for Use". (Page 78 to 93)
Application Circuits
NOTICE
qThe circuit application examples in this publication are provided to explain representative applications of SHARP devices and are not intended to guarantee any circuit design or license any intellectual property rights. SHARP takes no responsibility for any problems related to any intellectual property right of a third party resulting from the use of SHARP's devices. qContact SHARP in order to obtain the latest device specification sheets before using any SHARP device. SHARP reserves the right to make changes in the specifications, characteristics, data, materials, structure, and other contents described herein at any time without notice in order to improve design or reliability. Manufacturing locations are also subject to change without notice. qObserve the following points when using any devices in this publication. SHARP takes no responsibility for damage caused by improper use of the devices which does not meet the conditions and absolute maximum ratings to be used specified in the relevant specification sheet nor meet the following conditions: (i) The devices in this publication are designed for use in general electronic equipment designs such as: --- Personal computers --- Office automation equipment --- Telecommunication equipment [terminal] --- Test and measurement equipment --- Industrial control --- Audio visual equipment --- Consumer electronics (ii)Measures such as fail-safe function and redundant design should be taken to ensure reliability and safety when SHARP devices are used for or in connection with equipment that requires higher reliability such as: --- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.) --- Traffic signals --- Gas leakage sensor breakers --- Alarm equipment --- Various safety devices, etc. (iii)SHARP devices shall not be used for or in connection with equipment that requires an extremely high level of reliability and safety such as: --- Space applications --- Telecommunication equipment [trunk lines] --- Nuclear power control equipment --- Medical and other life support equipment (e.g., scuba). qContact a SHARP representative in advance when intending to use SHARP devices for any "specific" applications other than those recommended by SHARP or when it is unclear which category mentioned above controls the intended use. qIf the SHARP devices listed in this publication fall within the scope of strategic products described in the Foreign Exchange and Foreign Trade Control Law of Japan, it is necessary to obtain approval to export such SHARP devices. qThis publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, in whole or in part, without the express written permission of SHARP. Express written permission is also required before any use of this publication may be made by a third party. qContact and consult with a SHARP representative if there are any questions about the contents of this publication.
115


▲Up To Search▲   

 
Price & Availability of GL390

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X